Ahmet Alptekin Kasar
Founder, Managing Director
Updated: 2026-11-25
This page is for people who prepare construction documentation, designers, energy consultants and contractors: whoever specifies the materials in a Wekerle+ design and puts the documentation together.
What a declaration of performance is and what it contains
A declaration of performance (DoP) is the manufacturer's document under Regulation (EU) No 305/2011. The manufacturer issues it for a construction product covered by a harmonised standard and declares the product's essential characteristics in it. CE marking rests on that declaration: the mark shows that the product is placed on the market with the performance declared in the DoP.
From a DoP a designer needs four things: the product type and declaration number, the intended use, the harmonised standard, and the table of declared values. The ODE Starflex glass wool declaration, for example, is No. 101 and refers to EN 13162:2012+A1:2015; the AVCP systems are 1 and 3, and the notified bodies are TZÚS (NB 1020) and TEBAR (NB 2164).

Our article on DoP and CE documents has the general checklist. This page covers what goes from it into the folder of a Wekerle+ design.
Which values go on the drawings
Drawings and specifications take the declared value, not a rounded catalogue figure. For insulation that is the declared thermal conductivity (λD); for membranes it is the water-vapour diffusion-equivalent air layer thickness (Sd). Where the DoP declares it, the water resistance class or water column also belongs in the specification, and the reaction-to-fire class should always be taken from the manufacturer's DoP.
| Group | Product | Data |
|---|---|---|
| Insulation | ODE Starflex glass wool | λD 0.039 W/(m·K); 2 × 12.5 cm, second layer cross-laid; CE, EUCEB |
| Insulation | ODE Rockflex stone wool | Technical data per the manufacturer's DoP, on request |
| Vapour control | BK45 vapour barrier | 45 g/m², Sd 20 m, W1; warm side, on every ceiling; CE, EN 13859-1/2 |
| Vapour control | BD70 breathable membrane | 70 g/m², Sd 0.02 m, 259 mm H₂O; CE, EN 13859-1/2 |
| Documents | Downloadable DoP | BK45 and BD70 declarations of performance (PDF); ODE DoP and data sheet on request |
Source: ODE Yalıtım and EuConX (BK45, BD70) product data, declarations of performance.
Product by product: what the specification should say
For ODE Starflex glass wool, the specification states λD 0.039 W/(m·K), the build-up (two 12.5 cm layers, the second laid crosswise so the joints do not line up) and the CE and EUCEB marks. The design sets the thickness; 2 × 12.5 cm is the build-up of our attic package.
BK45 vapour barrier: 45 g/m², Sd 20 m, W1, CE, EN 13859-1/2. It goes on the warm side of the insulation, on every ceiling. It helps to mark the membrane's position on the drawing, along with taped overlaps and junctions.
BD70 breathable membrane: 70 g/m², Sd 0.02 m, 259 mm H₂O, CE, EN 13859-1/2. It protects the insulation on the colder, outer side and lets moisture out. Read together, the two Sd values show the logic of the build-up: closed on the inside, open on the outside.
For stone wool (ODE Rockflex) we publish no figures here: the data comes from the manufacturer's DoP, on request. The specification logic itself, when to choose glass wool and which vapour control to pair with it, is covered in our article for energy consultants.
One product, one name, one DoP, one delivery note
A data pack only works if the design, the DoP and the delivery describe the same product. In practice that means three matches:
- Product name: the specification uses the same name as the DoP and the delivery note.
- DoP number: the folder holds the declaration that applies to the product delivered.
- Delivery: each line on the delivery note can be traced back to a line in the specification, filed per building.

If a product in the specification is swapped during the job, the DoP changes too, and the affected lines of the design need updating. In the EKR programme we supplied materials to contractors, with the paperwork for every delivery; that work showed us that a swap creates most of its follow-up work on the documentation side. EKR is currently suspended.
Downloadable documents
| Product | Document |
|---|---|
| BK45 vapour barrier | BK45 declaration of performance (PDF) |
| BD70 breathable membrane | BD70 declaration of performance (PDF) |
| ODE Starflex glass wool | DoP and data sheet on request |
| ODE Rockflex stone wool | DoP and data sheet on request |
We send requested documents on the same working day. The same documents travel with each delivery; material comes from Turkey in 3–5 days of transit (about 5 on average), with delivery anywhere in Hungary.

If the design includes attic-floor insulation, our own offer is a reference point: 12,700 Ft/m² gross, with BK45 vapour barrier (Sd 20 m) on every ceiling, 25 cm of glass wool and BD70 breathable membrane (Sd 0.02 m). Walkways are an extra item on request; clearing, repairs and difficult access are also extra, and the final price follows a survey. We supply the materials and our contractor partner installs them. Material-cost planning is covered in our Wekerle+ material cost planning article.
Wekerle Panel and Condominium Programme
Government Decision 1359/2026. (XI. 3.) lists, among the elements of the programmes, the "application of prequalification to the preparers of construction documentation and to contracting builders". According to wekerle.kormany.hu, condominiums receive an interest-free loan and a non-repayable grant; the "What can it be used for?" list names thermal insulation as well as design and technical supervision, and the start is March 2027. Whether a building or a work item is eligible is decided by the call.
Prequalification is covered in our prequalification article; the full material list in the Wekerle+ material checklist and the panel block material list. Material supply under the renovation grant is covered in our home renovation grant 2027 article (in Hungarian), procurement risk in our article on EKR procurement risk, and the EKR background on the EKR programme page; partner terms are on the Wekerle+ partner page.
Request the data pack
Send the planned build-up and the products you need a DoP or data sheet for: partner quote request · +36 30 485 0258 · info@euconx.com. We reply on the same working day.
Frequently asked questions
What is a declaration of performance (DoP)?
The manufacturer's declaration under Regulation (EU) No 305/2011, declaring the product's essential characteristics against the harmonised standard. CE marking rests on it.
Which value goes on the drawing: the catalogue figure or the DoP figure?
The value declared in the DoP: λD for insulation, Sd for membranes. For ODE Starflex glass wool that is λD 0.039 W/(m·K).
Where can I download the BK45 and BD70 DoPs?
The BK45 DoP and the BD70 DoP are available as PDFs. BK45 has an Sd value of 20 m, BD70 of 0.02 m.
How do I get the ODE documents?
We send the DoP and data sheet for ODE Starflex and Rockflex on request, on the same working day.
Why must the product name match on the DoP and the delivery note?
Because only then does the folder show that the product installed is the one the design specified. After a swap, update both the DoP and the affected lines of the design.
Do I have to use EuConX documents in the programme?
No. These documents cover our products. Whether a building or a work item is eligible is decided by the call.
Sources
1. National Legislation Database (NJT): Government Decision 1359/2026. (XI. 3.) on launching the Wekerle Panel Programme and the Wekerle Condominium Programme (point 1 f), in Hungarian)
2. wekerle.kormany.hu (Wekerle+ Condominium and Panel Programme: interest-free loan and non-repayable grant, "What can it be used for?", start; in Hungarian)
3. ODE Yalıtım: glass wool declaration of performance No 101 (EN 13162:2012+A1:2015)
4. EuConX: BK45 and BD70 declarations of performance, product data, delivery data and company data
Planning a project? Let’s talk.
Send the material schedule or project requirements. We’ll help match the product and prepare a clear quotation.