EuConX Editorial
EuConX Editorial
Plinth and base-slab details are where moisture, frost and soil load meet. If an insulation board takes up water below the damp-proof course, its thermal resistance drops and a thermal bridge opens around the perimeter.
Why perimeter insulation needs closed-cell XPS
Fibrous insulation and standard EPS are poor choices in permanent contact with ground moisture. Extruded polystyrene (XPS) has a closed-cell structure, so it is the usual board for basement walls, plinths and inverted roofs, where it must stay dry in service and carry load. For below-ground work, check two things on the Declaration of Performance: the declared compressive strength and the declared thermal conductivity. Where EPS is enough and where XPS is needed, with the declared figures side by side: XPS vs EPS for plinths and basement walls.
ODE Yalıtım produces the ODE Isıpan XPS line in Türkiye. EuConX supplies it to Hungarian contractors and developers with the manufacturer's CE documentation and Declaration of Performance. You can see the ODE Isıpan XPS board in the product range, including the producer's datasheet links.
Core specifications
- Applications: facade, terrace and inverted roof, roof insulation, basement and retaining (reinforced-concrete) walls, and green roof.
- Thermal conductivity: λ from 0.035 W/(m·K).
- Compressive strength: PRM 300, which is 300 kPa at 10 % deformation.
- Standard and fire class: EN 13164, Euroclass E.
- Thickness: a range of thicknesses, specified per project. Tell us your U-value target and we propose the build-up.
- Green roof: the closed-cell board copes with moisture and substrate load, so the insulation keeps working under soil and planting.
Fire class E means XPS is not a facade-cladding or escape-route solution on its own. Use it where the design calls for ground-contact, inverted-roof or plinth insulation, and keep non-combustible products for walls where the fire design asks for them. Our guide to mineral wool and glass wool on facades covers that choice.
Choosing the board for the detail
For a plinth, decide the depth of the insulation below ground, the finish above ground and the waterproofing layer behind the board before you choose a thickness. To compare thicknesses against a U-value target, use the lambda and thickness calculation guide or the calculator. Where the slab or wall also needs waterproofing, read the ODE Epikon Proof guide for the membrane side of the foundation.
Request a quote
Send the area, thickness, application and delivery city. We reply the same working day with the DoP and datasheet links for the board. Contact EuConX, write to info@euconx.com or call +36 30 485 0258.
Planning a project? Let’s talk.
Send the material schedule or project requirements. We’ll help match the product and prepare a clear quotation.