This piece is for prefab house manufacturers, timber-frame contractors and buyers ordering insulation for one house or for a year. The figures come from the EuConX technical datasheets; we supply both materials from pallet lots to full trucks.
Thermally they are close
The ODE Starflex Glass Wool Roll 035 has λD 0.035 W/(m·K) and a declared thermal resistance of RD 2.85 m²K/W at 100 mm. The Bonus Premium F 120 Stone Wool Board has λD 0.037–0.038 W/(m·K) and RD 2.60 m²K/W at 100 mm. At the same thickness the roll is slightly better, but that is not what decides. In a 140 or 160 mm stud wall the choice comes from the construction, the production line and transport.
The truck decides the cost per square metre
Glass wool rolls travel compressed; stone wool boards do not. A full 13.6 m truck carries 4,118 m² of 100 mm glass wool roll, or 824 m² of 100 mm stone wool board. For the same area, stone wool needs five times as many loads. Density tells the same story: 18 kg/m³ against 120 kg/m³, that is 1.8 kg against 12 kg per square metre at 100 mm.
Freight is priced per truck, so freight per square metre falls as more square metres fit in. The plant's warehouse sees the same ratio: one truckload of rolls insulates five times as much wall as one truckload of boards.
On the line, rolls are fast and boards are rigid
Rolls are cut to the stud spacing and laid into the bay slightly compressed, where their spring holds them. Boards are rigid and dimensionally stable (DS(70,-)), and their face can take load: the stone wool board has a tensile strength perpendicular to faces of TR10. That is why stone wool goes where render or anchors go onto the insulation, and glass wool goes where a bay must be filled quickly and without gaps.
For partitions, order boards rather than rolls. The ODE Evomineral Glass Wool Partition Board 037 is 600 × 1200 mm, clamps between the studs and does not slump.
Fire: both are A1, the difference is in the system
The ODE glass wool and Bonus stone wool products supplied by EuConX are both Euroclass A1 under EN 13501-1: they make no contribution to fire. Fire resistance (such as REI 30 or REI 60) is a property of the whole wall, not of the material. It is proven by a test and a classification report, which names the insulation type and its density.
If a tested wall build-up specifies stone wool, it cannot simply be swapped for glass wool, nor the other way round. Check the system documents or the project's fire concept before ordering. Our article on A1 stone wool in timber frames goes into detail.
What goes where
Glass wool rolls go into stud bays, between rafters and into floor cassettes, with the denser 032 roll in the thin service cavity. Stone wool boards go into rendered external insulation and into zones that need non-combustible insulation. A prefab house usually needs both, so they can share a truck. Our article on DAP truck supply covers the delivery side.
Frequently asked questions
Which insulates better, glass wool or stone wool?
For EuConX products at 100 mm, the glass wool roll has RD 2.85 and the stone wool board RD 2.60 m²K/W. The gap is small; construction, production and transport decide.
Why is stone wool freight higher per square metre?
Because it cannot be compressed. A full truck carries 4,118 m² of 100 mm glass wool roll or 824 m² of 100 mm stone wool board, so the same area needs five times as many trucks.
Is glass wool A1 as well?
Yes. ODE Starflex and Lunaflex rolls and ODE Evomineral partition boards are Euroclass A1 under EN 13501-1, as stated in the declaration of performance.
Can I replace stone wool with glass wool in a fire-rated wall?
Only if the wall's classification report or the fire concept allows it. Fire resistance belongs to the whole construction, and the report names the insulation type.
Can glass wool and stone wool travel on one truck?
Yes, a mixed load can be arranged. Give the thickness and quantity per product in your enquiry and we put the load together.
Sources
1. EuConX technical datasheets (λD, RD, density, m² per truck, Euroclass): https://euconx.com/en/products/datasheets
2. Commission Decision 2000/147/EC on the classification of the reaction to fire performance of construction products: https://eur-lex.europa.eu/eli/dec/2000/147/oj
3. Regulation (EU) No 305/2011 (construction products, CE marking, declaration of performance): https://eur-lex.europa.eu/eli/reg/2011/305/oj
Planning a project? Let’s talk.
Send the material schedule or project requirements. We’ll help match the product and prepare a clear quotation.