EuConX mineral wool
Bonus Premium F 120 Stone Wool Board
A rigid, unfaced stone wool board for facades and timber-frame external walls. Euroclass A1, non-combustible and vapour-open (MU 1).
- Thickness
- 50 / 70 / 80 / 100 mm
- λD W/(m·K)
- 0.037–0.038
- Euroclass
- A1
Technical data
- Thermal conductivity λD, W/(m·K)
- 0.037–0.038
- Thickness
- 50 / 70 / 80 / 100 mm · manufacturer range 30–130 mm, other thicknesses on request
- Format
- 600 × 1,200 mm
- Reaction to fire (Euroclass)
- A1
- Standard
- EN 13162
- Marking
- CE, declaration of performance (DoP)
- Tensile strength perpendicular to faces (EN 1607)
- TR10 (≥ 10 kPa)
- Thickness tolerance (EN 823)
- T5
- Short-term water absorption (EN ISO 29767)
- WS ≤ 1 kg/m²
- Long-term water absorption (EN ISO 16535)
- WL(P) ≤ 3 kg/m²
- Water vapour diffusion resistance (EN 12086)
- MU 1
- Dimensional stability (EN 1604)
- DS(70,-)
- Density (EN 1602)
- 120 kg/m³ ± 10 %
- Supply
- Pallet or full truck (13.6 m), DAP to the address you name

Thicknesses
- 50 mmBoard
- Format (w × l)
- 600 × 1,200 mm
- λD W/(m·K)
- 0.037
- RD m²K/W
- 1.35
- Density
- 120 kg/m³
- Compressive strength (EN ISO 29469) kPa
- 35
- m² / truck (13.6 m)
- 2,534.4
- 70 mmBoard
- Format (w × l)
- 600 × 1,200 mm
- λD W/(m·K)
- 0.037
- RD m²K/W
- 1.85
- Density
- 120 kg/m³
- Compressive strength (EN ISO 29469) kPa
- 35
- m² / truck (13.6 m)
- 1,140.48
- 80 mmBoard
- Format (w × l)
- 600 × 1,200 mm
- λD W/(m·K)
- 0.037
- RD m²K/W
- 2.15
- Density
- 120 kg/m³
- Compressive strength (EN ISO 29469) kPa
- 35
- m² / truck (13.6 m)
- 950.4
- 100 mmBoard
- Format (w × l)
- 600 × 1,200 mm
- λD W/(m·K)
- 0.038
- RD m²K/W
- 2.60
- Density
- 120 kg/m³
- Compressive strength (EN ISO 29469) kPa
- 50
- m² / truck (13.6 m)
- 823.68
Where it goes

ETICS facades
Rendered external insulation on masonry and timber-frame walls: the board is bonded and anchored, tensile strength TR10.
Where insulation must be non-combustible
Euroclass A1: fire barriers, zones around openings and compartment lines, wherever the project's fire concept asks for it.
Timber-frame and prefab houses
The external insulation layer on wall elements, fitted in the factory if needed; vapour-open (MU 1), so it does not trap moisture in the timber.
Technical datasheet
Every thickness with λD, RD, pack and truck quantities, ready to print.

A quote for your volume
Send the thickness, the annual quantity (m²) and the delivery address. We reply the same working day.