Ahmet Alptekin Kasar
Founder, Managing Director
Updated: 2026-11-20
This piece is for anyone specifying or ordering glass wool rolls for a production line, a roof or a floor. German and Austrian tenders ask for the same thing as WLG 040 or WLS 035: the number is the thermal conductivity in thousandths of W/(m·K).
The formula is simple, the decision is not
Declared thermal resistance is RD = d ÷ λD. 0.040 ÷ 0.035 = 1.14, so a 0.040 roll needs a 14% thicker layer for the same R. Whether that matters depends on the depth of the construction.
In a timber-frame wall the stud depth is fixed. If it is 140 mm, the bay gets 140 mm of insulation, no more and no less. Here λ goes straight into the U-value, and the 0.035 roll is the better choice. On floors, cold lofts or between deep joists the thickness can grow, and there the 0.040 class gives the same R, only thicker.
What the datasheets show
Declared values of the two ODE Starflex roll classes, with the quantity that fits on a full 13.6 m truck:
| Roll | Thickness | RD (m²K/W) | m² per truck |
|---|---|---|---|
| ODE Starflex Glass Wool Roll 035 | 100 mm | 2.85 | 4,118 |
| ODE Starflex Glass Wool Roll 035 | 140 mm | 4.00 | 2,978 |
| ODE Starflex Glass Wool Roll 035 | 160 mm | 4.55 | 2,534 |
| ODE Starflex Glass Wool Roll 035 | 240 mm | 6.85 | 1,774 |
| ODE Starflex Glass Wool Roll 040 | 60 mm | 1.50 | 8,448 |
| ODE Starflex Glass Wool Roll 040 | 100 mm | 2.35 | 7,920 |
| ODE Starflex Glass Wool Roll 040 | 200 mm | 5.10 | 3,041 |
Source: EuConX technical datasheets.
At 100 mm the 040 roll gives 82% of the 035 roll's thermal resistance, but 92% more square metres fit on a truck. The truck price is fixed, so freight per square metre falls by almost half. On large floor areas this often weighs more than a few extra centimetres of thickness.
When to use which
Wall elements with a fixed stud depth, and rafters where the roof height sets the limit: ODE Starflex Glass Wool Roll 035, 100, 140, 160 or 240 mm. Floor cassettes, cold lofts and large open areas: ODE Starflex Glass Wool Roll 040, 60, 100 or 200 mm. The service cavity on the inside of walls, where there are only 40 mm: ODE Lunaflex Glass Wool Roll 032, RD 1.25.
Two layers add up too: 2 × 100 mm of the 040 roll gives RD 4.70, more than the 4.55 of a 160 mm 035 roll, only 40 mm thicker.
What to put in the enquiry
Thickness, the required λD or RD, the annual quantity in square metres and the delivery address. If a tender asks for WLG 040, check the declared value per thickness: the 035 roll complies at every thickness, while in the 040 family the 60 mm version has λD 0.040, the 200 mm version λD 0.039, and for 100 mm the datasheet declares RD 2.35. We price both families and settle the choice with you based on the construction depth.
Frequently asked questions
What does WLG 040 mean?
In German tenders it is the thermal conductivity group: λ at most 0.040 W/(m·K). WLS 035 likewise means 0.035. A 035 product complies with a WLG 040 tender.
How much thicker must a 0.040 roll be for the same thermal resistance?
14%: 0.040 ÷ 0.035 = 1.14. Instead of 100 mm of a 0.035 roll you need about 115 mm of a 0.040 roll.
Why do more square metres of the 040 roll fit on a truck?
It is lighter, at 12 kg/m³, and compresses more. 7,920 m² of 100 mm fit on one truck, against 4,118 m² of the 035 roll.
Which roll goes into a 140 mm stud wall?
Where the depth is fixed, the λ 0.035 roll. At 140 mm it has RD 4.00 m²K/W.
Can rolls be laid in two layers?
Yes, it is common on floors and lofts. 2 × 100 mm of the 040 roll gives RD 4.70 m²K/W, laid with staggered joints.
Sources
1. EuConX technical datasheets (λD, RD, density, m² per truck): https://euconx.com/en/products/datasheets
2. EN 13162: Thermal insulation products for buildings. Factory made mineral wool (MW) products. Specification
Planning a project? Let’s talk.
Send the material schedule or project requirements. We’ll help match the product and prepare a clear quotation.